A fire extinguisher needs refilling on two accounts:

First: If the fire extinguisher is used, even partially, it is useless in case of a subsequent fire scenario. Hence it is essential to get the fire extinguisher recharged immediately, without any delay.

Second: The statutory framework in the country makes it mandatory for the shell of the fire extinguisher to undergo Hydrostatic Pressure Test every 3 years.

When is Refilling of Fire Extinguishers is required?

Fire extinguishers need to be recharged immediately after each use

If the extinguishing agent inside was not completely discharged, the extinguisher still needs to be serviced in order to make sure it’s ready for its next use

Fire extinguishers need to be recharged periodically throughout their life

The statutory framework in the country makes it mandatory to refill your fire extinguisher

Our Refilling Process

STEP 01

The Fire Extinguishers are discharged for emptying the content, meantime extinguishers performance also checked.

STEP 02

Then the extinguisher is dismantled / disassembled completely and cylinder is cleaned for any trace of content inside the cylinder.

STEP 03

Then the cylinder undergoes a Hydro Static Pressure Test at 35 bar for 2.5 minutes to check for leaks and the strength of welding quality.

STEP 04

The cylinder subjected for semi-automatic powder coating process and then baking in Oven at 200 degrees for 10 minutes. This gives the new look, super fine quality and durable new paint surface on the cylinder.

STEP 05

Fresh extinguishing Medium such as Dry Chemical powders, Gas, Water or various types of Foams filled in the cylinder through vacuum based a process that fills the cylinder with accurate amount of extinguishing agent.

STEP 06

Then the extinguishers are assembled with discharge valve by torque wrench to maintain the fitment accuracy and all the O’ Rings are replaced with new ones.

STEP 07

Fire extinguisher is charged / pressurized with UHP grade 99.99% pure nitrogen mixed with helium.

STEP 08

Then the fire extinguishers are subjected to dual leak test process i.e. Inverted Glass Jar leakage test in water and Mass Spectro Meter Helium Leak Detection Test.
Type Of Fire Extinguisher Refilling Services
Abc Fire Extinguisher Refilling Services
ABC Fire Extinguisher Refilling Services
  • Fire Extinguisher Type: ABC
  • Service Type: Refilling Service

About ABC Fire Extinguisher Refilling Services…

We provides refilling services to the ABC type of fire extinguishers and gives its utmost efforts to take care of clients’ requirements while delivering the services. We at Hridhi Corporation have employed an enthusiastic staff who always serves the clients with a smile and ensure optimum satisfaction of our clients.

Co2 Fire Extinguisher Refilling
  • Fire Extinguisher Type: Co2
  • Service Type: Refilling Service

We at Hridhi Corporation have engaged ourselves in offering CO2 Fire Extinguisher Refilling Service with the help of our skilled professionals incorporating high-grade equipment and advanced techniques. The Hridhi Corporation refilling service for a fire extinguisher is highly in demand by our clients due to its cost-effectiveness and promptness. Our team of professionals follow all the parameters associated with this fire extinguisher refilling service and perform the same in the best possible manner.

Other Fire Extinguisher Refilling Service

Hridhi Corporation is also indulged in providing refilling services for some other kinds of fire extinguishers. Fire extinguisher refill price on Hridhi Corporation is affordable to avail. Our team of professionals puts their best efforts to meet the requirements of clients with the committed time frame. Apart from ABC type and CO2 type fire extinguisher, we also provide refilling services for other extinguisher types, which are as follows:

  • DCP Powder Type
  • Mechanical Foam Type
  • Water Type
  • Modular Type
  • Class K Type
  • Clean Agent Type
Don’t Be Shy! Ask Us A Question